Systems

Stone 40-50mm ‘Secret-Fix’ systemONE

Vertical application
Concealed fix
Floor to floor
Heavy materials

SystemONE is engineered to support large cavities and where there is a need to span between floors. SystemOne is also used if building substrate is variable or where a subframe needs to carry heavy weight facade materials - including natural stones with a typical thickness greater than 40mm and glass. Use Fischer FZP undercut anchors to secure the panel to the hanger brackets.

The horizontal rail can be fixed to the vertical rail using tek screw or rivet connections. The horizontal rails are designed to span 600-800mm between the vertical support structure.

FischerBWM systemONE, horizontal rail system is available in 37mm deep sections, with hanger brackets available in 50mm, 90mm and 140mm widths. FischerBWM engineering will specify the hanger brackets depending on the façade panel size and weight.

Bracket and rail systems from Fischer are interchangeable based on the project requirement. 'Helping Hand' brackets from systemONE, concrete range, are the example in the image. SystemONE ‘Helping Hand’ brackets and vertical rails are specified where there is a requirement to span between floors and supports heavy facade materials. To achieve improved thermal performance to concrete substrate use ZeLa or ATK 100 stainless brackets.

FischerBWM offer Europe’s largest range of Helping hand brackets which have been designed to help achieve the U-value. Bracket systems range from the ZeLa range, designed to achieve passive house levels of performance, to standard L brackets that suit most project requirements in the UK.

Project thermal calculations to confirm insulation thickness available on a project by project basis.

Enquire Now
  • Approvals
  • Typical Façade Types
  • Technical Characteristics
  • Approvals

     

    FischerBWM facade systems are designed and manufactured to Eurocode 9. UK accreditation approvals through the new Winmark Approval, by Wintech and the BBA are confirmation of Eurocode design and manufacture processes.

     

    UK accreditation

    Winmark Approval

    British Board of Agrément (BBA) – Stage 2 progressing

     

    European accreditation

    MPA National Technical Test Certification: FischerBWM aluminium profile sections in substructure systems and connections

    Certification Conformity Structural Components and systems for structures to EXV2 according to EN 1090-2, for load-bearing structures in all types of buildings

    Passivhaus Certification

    CE-Certification & QM-cert ISO 9001

    Environmental management standard ISO 14001

  • Typical Façade Types

    Stone 40-50mm in thickness

     

    Types include:

    Dura Limestone

    Travertine

    Granite

    Marble

    Faience

    Ceramic

  • Technical Characteristics

     

    Typical bracket configuration uses the Fixed Point bracket at the highest position on the vertical rail to support the façade vertical dead loads. The Sliding Point bracket is used typically on all other positions on the vertical rail to absorb the project wind loading. Bracket configuration is specified by FischerBWM engineering department. To submit your project specifics please go to Contact.

    FischerBWM design issued by Fischer Engineering department are covered by Product and design insurance

    System components available for AutoCAD downloads.

    RJ & Fischer offer a standard, available ex stock UK, range that covers most design requirements.

    All rails available to specific RAL colours in Qualicoat on an order to order basis.

     

    Material Specification

     

    Manufactured from extruded aluminium alloys conforming to EN 573-3 (material) and EN 755 production standards.